EV-201
Reference
Complete charging unit shown for context. Supply scope covers the enclosure and agreed mechanical hardware only; charging modules, guns/connectors, EVSE controls, electrical-system assembly and commissioning are outside our current scope.
EV Charging Enclosures
Split-System DC Power Cabinet
Remote power-block housing for modular DC fast-charging systems.
The power-side enclosure for a split DC fast-charging system. One weatherproof cabinet can house the customer's AC-to-DC power modules, switchgear, metering, controls and communications while DC feeders run to remote charging dispensers. Single- or multi-bay layouts are arranged around the module stack, airflow, cable bend radius and service clearances.
Typical applications: Highway hubs, fleet depots, bus and truck charging, public fast-charging stations and sites where the power block is separated from the user-facing dispensers
- Modular one- to three-bay power-block layout
- Removable side and rear panels for module service
- Filtered ventilation or closed-loop cooling interfaces
- Separated AC input, DC output and communications zones
- Lockable double doors, lifting points and reinforced plinth
- Powder-coated carbon steel or 304/316 stainless exterior
Reference specification
Charging enclosure reference specification
Dimensions, material, finish, hardware, integration scope, IP target, certification, MOQ, and lead time are quoted against the approved drawing and final component BOM.
Send your requirement| Power-system fit | Split-system DC fast charging; customer-defined power modules, switchgear and controller |
|---|---|
| Reference envelope | Single bay approx. 1000 W x 900 D x 2200 H mm; one- to three-bay layouts project-specific |
| Frame and skin | 1.5-3.0 mm galvanized or cold-rolled steel; 304/316 stainless on request |
| Protection | IP54 typical; IP55/IP65 subject to thermal design and tested configuration |
| Impact | Door and face package can be engineered for IK10; final scope confirmed by drawing |
| Thermal management | Filtered front-to-back airflow, fan/filter units, AC cooling or liquid-cooling interfaces |
| Service access | Double front doors, removable side/rear panels, heavy hinges and multi-point locks |
| Cable entry | Bottom gland plate with separated AC input, DC output, auxiliary and communications routes |
| Mounting | Reinforced plinth, anchor points, fork pockets and lifting provisions as specified |
| Finish | Zinc-rich primer and UV-stable powder coat; coating system selected for C3-C5 exposure |
| Environment | Reference design basis -30 to +50 C, up to 95% RH non-condensing and 2000 m altitude |
| Design review | IEC 61851-23, IEC 61439, IEC 60529 and IEC 62262 as applicable project references |
| Scope | Enclosure, doors, seals, ventilation, finish and agreed hardware; power modules and electrical assembly excluded |
| Packing | Protective film, desiccant, foamed corners, braced pallet or export crate |
Reference image and specification. The final product is confirmed by approved drawing, samples, component selection, test scope, and order documentation. IP ratings and certifications are not implied unless stated in the quotation.
Related products
More formats in the same product line.
Custom version
Have a drawing, reference product, or application?
Send what you have. We will identify the production route, integration scope, missing details, and next steps.