"Outdoor cabinet, IP65, powder coated" is a common first specification. It is also incomplete. The rating, the coating and the steel are bought from three different processes, and a problem in any one of them will fail the finished cabinet regardless of what the drawing says.

Sheet-metal workshop with formed cabinet panels on the ENERAREA factory floor
Formed panels waiting for the next operation. Material and gauge decisions are locked in long before the cabinet reaches the coating line.

Start with where the cabinet lives

The operating environment decides the rest. An indoor kiosk in a climate-controlled mall and an energy-storage cabinet on a coastal site have almost nothing in common. Write down temperature range, humidity, salt exposure, dust, direct sun, cleaning method, and whether water can ever reach a door or cable entry. Without that list, an IP number is a guess.

1. Material: what the steel actually needs to do

Cold-rolled steel with powder coating is the default for indoor and sheltered equipment. It is economical, forms cleanly and takes a wide range of finishes. Galvanized steel adds corrosion resistance before the coating, which matters when the coating is chipped during installation or service. Stainless is a different cost class and is usually chosen for cleaning chemicals, coastal exposure or a specification that names it directly.

Gauge is a separate decision. A 1.5 mm door on a 900 mm frame behaves differently from a 2.0 mm door on the same frame. Large flat panels need stiffness from forming or reinforcement, not only from thicker sheet. Ask for the gauge of each major panel and the method used to control oil-canning.

2. Finish: protection plus appearance

Powder coating is a robust general choice for sheet-metal cabinets. Wet paint is easier to touch up on site and can suit small batches or large parts that do not fit the coating line. Neither is automatically better; the right answer depends on the service environment and the repair plan.

For any coated cabinet, ask about the pre-treatment sequence, the dry film thickness, and how edges and inside corners are covered. A coating specification that names only the RAL colour leaves the durability decisions to the supplier.

3. Ingress protection: what IP54 and IP65 really change

IP54 protects against dust ingress in quantities that will not interfere with operation, and against splashing water from any direction. IP65 adds a dust-tight enclosure and protection against water jets. On a cabinet, the number is delivered by gaskets, door compression, cable glands, seams and hardware — not by the sheet thickness alone.

What has to change to move from IP54 to IP65

  • Continuous gasket around every opening, with a defined compression.
  • Door stiffening so the gasket is loaded evenly along its length.
  • Rated cable glands and sealed unused entries.
  • Sealed hinges and locks, or covers at the fixing points.
  • Control of weld seams and panel joints on the protected side.
  • A documented verification method agreed before production.

If only the door is sealed while the cable entry remains open, the cabinet does not reach the rating. This is the most common gap we see in incoming specifications.

An IP rating is a system property. Specify the door, the glands, the seams and the test — not only the number.

4. Put the three decisions together

For a sheltered indoor terminal, cold-rolled steel with a standard powder coat and no formal IP rating is often sufficient. For an outdoor enclosure in a wet or dusty site, galvanized or coated steel, a specified finish system, IP65 construction and a verification plan should be written together. Choosing them one at a time is how cost is added in the wrong places.

A short pre-quote checklist

  • Operating environment and cleaning method.
  • Gauge of doors, panels and frame.
  • Base material and any mill certificate requirement.
  • Finish system: pre-treatment, coating type, dry film, colour approval.
  • Required IP rating and which openings it must cover.
  • Gasket, gland and lock requirements.
  • How the rating will be verified before shipment.

Send these seven points with your next drawing or reference photo. We can then separate what is required from what is assumed, and identify where a lower-cost choice will still meet the service condition.

Continue with material and finish